© 2016 SPI Lasers UK Ltd.
Commercial in Confidence
SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
Output Function Description
Parameter Set / Process Cycle
Selected (Bit 3)
Parameter Set / Process Cycle
Selected (Bit 4)
Parameter Set / Process Cycle
Selected (Bit 5)
Safe Mode Recovery Active
Burn Back / Safe Mode detected
True: Condition detected
False: Condition not detected.
True: One of monitored temperatures above
Alarm level.
Process Cycle Active Step
(Bits 0 - 9)
7.6.5.7 Analogue Input
The waveform applied between Pins 11 and 24 can be used to control the demanded output
power. This is referred to as External Power Control (EPC). The Machine Interface needs to
have an external power supply connected between Pins 1 or 2 and 14 or 15 for this function to
operate. The active pulse shape must also be set into EPC mode using FiberView. (Refer to
Section 9.3.8.)