SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
52
ID
Output Function Description
Comments
14
Parameter Set / Process Cycle
Selected (Bit 3)
15
Parameter Set / Process Cycle
Selected (Bit 4)
16
Parameter Set / Process Cycle
Selected (Bit 5)
17
Scanner Start Output
18
Ready To Start
Connected with no alarms
19
Emission Indicator
20
Not supported
21
Safe Mode Recovery Active
22
Not supported
23
Not supported
24
Not supported
25
Not supported
26
Not supported
27
Burn Back / Safe Mode detected
True: Condition detected
False: Condition not detected.
28
Laser Over Temperature
True: One of monitored temperatures above
Alarm level.
29
Not supported
30
Not supported
31
Not supported
32 -
41
Process Cycle Active Step
(Bits 0 - 9)
42
Not supported
Not supported
43
XPR Mode Enabled
7.6.5.7 Analogue Input
The waveform applied between Pins 11 and 24 can be used to control the demanded output
power. This is referred to as External Power Control (EPC). The Machine Interface needs to
have an external power supply connected between Pins 1 or 2 and 14 or 15 for this function to
operate. The active pulse shape must also be set into EPC mode using FiberView. (Refer to
Section 9.3.8.)

Table of Contents