To operate the redPOWER Fiber Laser use the buttons in the Tool bar. Click on the green
STANDBY Button to enable the redPOWER Fiber Laser. When the On Button turns black
(after a 5s safety delay), click on it to start laser emission.
To turn the redPOWER Fiber Laser OFF, click the red Off Button, or the green STANDBY
Button.
Note: Turning the redPOWER Fiber Laser ON from STANDBY is faster than from OFF.
9.3 Parameter Sets
9.3.1 Overview
Parameter Sets define the output of the redPOWER Fiber Laser. This section explains how
the different fields of the Parameter Set affect the output. The FVCU can store up to 50
Parameter Sets in its onboard memory for fast access when switching between Parameter
Sets during processing.
Each Parameter Set contains the following information:
Table 14 Parameter Set Attributes
Item
Information
Parameter Set
Identification String
A 16 character string giving the Parameter Set an identifying name.
(e.g. to store the name of the part the Parameter Set has been
developed to process)
Library Shape
Reference
The output style: either a Predefined shape or a User defined
shape
Mean Current Demand
Used for CW and Sine Wave output styles
Peak Current Demand
Used for Single Sector Pulse, Sine and User Defined Shape output
styles
Width
The pulse width duration for the Single Sector Pulse and User
Defined Shape output styles, scaled in microseconds, with a
maximum duration of 1s
Frequency
The maximum frequency that can be set is 50kHz
Ramp Up Time
The time to ramp up from the STANDBY to the ON state, with a
maximum of 10s
Ramp Down Time
The time to ramp down from the ON to the STANDBY state, with a
maximum of 10s
External Power
Control Enable
Selects between external analogue control and internal parameter
set control for output height. When external control is enabled, the
analogue input on the Machine Interface controls the output height

Table of Contents