Item
Information
External Power
Control Mode
Relative mode sets the external analogue control range between 0
and the relevant height of the active Parameter Set.
Absolute mode sets the external analogue control range between 0
and the maximum current demand
External Trigger
Source
Selects between internal and external Trigger sources. This is a
Local operating mode Trigger source select, and only has a bearing
on the output if the Machine Interface Trigger source select function
is not configured to an input when in Remote Control
Internal Trigger Select
The output is Triggered from the internal frequency generator at the
frequency determined by the active Parameter Set Frequency field
External Trigger Select
When the external Trigger input on the Machine Interface is set, the
output response is determined by the External Trigger Mode
External Trigger Mode
Edge Trigger Mode (when this mode is selected, the redPOWER
Fiber Laser will output a Single Pulse or User Defined Shape each
time a Machine Interface Trigger input is generated - input transition
from CLEAR to SET)
Gated Trigger Mode (when this mode is selected, the output will use
the active Parameter Set settings when a Machine Interface Trigger
input is asserted.) There is no output when the Machine Interface
Trigger input is clear. If a pulsed style shape is being used (Single
Sector Pulse or User Defined Shape), the frequency of the output is
determined by the internal frequency generator.
Parameter Sets can be edited using the Parameter Editor. Select by Parameter Editor Tab, or
View Windows Parameter Set Programming on Menu Bar.