Parameter
Min
Max
Units
Notes
Pressure Drop
-
2.5
bar
For QUBE Fiber Lasers having a long case.
Refer to Table 32
Table 26 Required Chiller Capacity
Rated Power
300W
500W
750W
1000W
1500W
Units
Chiller Capacity
0.9
1.5
2.3
3.0
4.5
kW
Table 27 Cooling Requirements (Connection to PIPA-Q Optical Connector)
Parameter
Min
Max
Units
Notes
Cooling Water
Temperature
15
35
ºC
It is important that condensation will not occur.
Refer to Section 17.1.
Input Pressure
-
6
bar
Flow Rate
0.5
2
l/min/kW
At 20°C water temperature.
Pressure Drop
1.6
5
bar
Chiller Capacity
0.5
-
kW
18 Optical Specifications
18.1 General Optical Specifications
Table 28 General Optical Specifications
Parameter
Units
Value
Rated Output Power (CW, EOL)
5
W
300, 500, 750, 1000, 1500
Electro-optical Conversion Efficiency (Nominal)
%
27%
Modes of Operation
-
CW
Analogue modulation
Digital modulation
Polarisation
-
Random
Central Emission Wavelength
nm
1075 ±7
Emission Bandwidth (FWHM)
nm
≤10
5
Rated output power for variants with bare fiber is increased by 4%