SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
50
ID
Input Function Description
Comments
3
Trigger / Gate Input
Recommended Configuration: Use
Input 6.
False: No laser Output.
True: Gated Mode: Laser output.
Triggered Mode: Laser pulse on rising edge.
4
Trigger Source Select (Internal /
External)
False: QUBE Fiber Laser runs at pulse rate
defined by internal parameters.
True: QUBE Fiber Laser is Triggered or
gated by Trigger Input
5
Process Cycle Step
Advances to next process step on rising
edge.
6
Alarm Reset
Resets Alarm condition on rising edge.
7
Strobe
Read parameter set / process cycle data
(ID8-ID14) on rising edge.
8
Parameter Set / Process Cycle Select
(Bit 0)
Parameter set or Process cycle can be
selected using these inputs. Only operational
in Remote Control.
9
Parameter Set / Process Cycle Select
(Bit 1)
10
Parameter Set / Process Cycle Select
(Bit 2)
11
Parameter Set / Process Cycle Select
(Bit 3)
12
Parameter Set / Process Cycle Select
(Bit 4)
13
Parameter Set / Process Cycle Select
(Bit 5)
14
Alignment Laser Demand
False: Alignment Laser OFF
True: Alignment Laser active
15
Scanner Start Input
16
Safe Mode Recovery Start
17
Not supported
18
XPR Mode Enable

Table of Contents