b) Process Cycle Operation
When the QUBE Fiber Laser is in Remote Control this input function provides the
following action:
o From the STANDBY state, setting the input starts a Process Cycle.
o From the Process Cycle Active state, clearing the input stops a Process Cycle.
If a ramp down time is set in the Parameter Set linked to the active Process
Cycle Step, the ramp down will commence when the Process Cycle Start input
is CLEARED and the state will transition to the STANDBY state.
When in STANDBY and switching into Remote Control the state of the Process Cycle
Start input is acted upon depending on the initial state.
o If the state is the STANDBY state, and the Process Cycle Start input is SET, a
Process Cycle will not start when entering Remote Control. In this case the
Process Cycle Start input is edge Triggered.
o If a Process Cycle is active when entering Remote Control it will stop
regardless of the Process Cycle Start input condition. If a ramp down time is set
in the Parameter Set linked to the active Process Cycle Step, when entering
Remote Control the ramp down will commence and the state will transition to
the STANDBY state.
o When the state is the OFF state, or transitioning to the STANDBY state, and
the Process Cycle Start input is SET, a Process Cycle will not start when it
enters STANDBY.
Care must be taken to ensure the Laser Start and Laser ON / Process Cycle Start
inputs (if configured) are in the correct state when entering Remote Control.
This function is only operational in Remote Control and when the state is the
STANDBY state. If this function is configured and SET, when the STANDBY state is
entered from the OFF state, the state will not transition to the ON state. The configured
input must be cycled to provide a leading edge to transition the state to the ON state.
This function has no effect if it is not configured on the Machine Interface.
This function can be assigned to any of the seven inputs.
Associated functions
o Laser Start - Input Function
o Laser STANDBY - Output Function
o Laser ON / Process Cycle Active - Output Function
o Remote Status - Output Function