redPOWER QUBE Cased Fiber Laser User Manual
111
o Output number 4
Basic Function Description
o SET when there is a warning condition.
o CLEAR when there is no warning condition.
o Operational in both Local and Remote Control.
Detailed Function Description
o This output is used to indicate when there is a Warning condition.
o This output function is SET for any warning condition. It is CLEARED when
there are no warning conditions.
o This function can be assigned to any of the seven outputs.
11.3.6 Energy Warning (Output Function ID 9) (Future Functionality):
Default connection
o PL5 pin number 9
o Output number 5
Basic Function Description
o SET when there is an energy warning condition.
o CLEAR when there is no energy warning condition.
o Operational in both Local and Remote Control.
Detailed Function Description
This output is used to indicate when there is an Energy Warning condition.
This function can be assigned to any of the seven outputs.
11.3.7 Process Cycle Wait (Output Function ID 5):
Default connection
o PL5 pin number 22
o Output number 6
Basic Function Description
o SET during a Process Cycle at the end of a manual transitions step to indicate
the Process Cycle is waiting for a Step input in order to continue.
o CLEAR at any other time.
o Operational in both Local and Remote Control.
Detailed Function Description