redPOWER QUBE Cased Fiber Laser User Manual
110
Detailed Function Description
o This output function is used to indicate whether the QUBE Fiber Laser is in
Remote or Local control mode. Remote Control indicates that the QUBE Fiber
Laser is monitoring and being controlled by the Machine Interface inputs. The
mode is Local control when the output is CLEAR, and Remote Control when
the output is SET.
o Some or all of the Local control functionality can be utilised when in Remote
Control, depending on the Machine Interface input configuration.
o The mode can only be changed between Remote and Local control via the
serial communications interface.
o This function can be assigned to any of the seven outputs.
Sequence diagrams
o See Figure 37 to Figure 64 for example functionality.
11.3.4 Alarm (Output Function ID 7):
Default connection
o PL5 pin number 8
o Output number 3
Basic Function Description
o SET when there is in an alarm condition.
o CLEAR when there is no alarm condition.
o Operational in both Local and Remote Control.
Detailed Function Description
o This output is used to indicate when there is an Alarm condition. It is cleared by
issuing an Alarm Reset command once the condition causing the alarm has
been cleared, from either a configured Machine Interface Alarm Reset input
function (SET under Remote Control) or an Alarm Reset serial command
message.
o This function can be assigned to any of the seven outputs.
o Associated function
Alarm Reset - Input Function
11.3.5 Warning (Output Function ID 8):
Default connection
o PL5 pin number 21