When the QUBE Fiber Laser is configured to ramp up via the Parameter Set, this
function will be SET when the ramp up starts, and remain SET until the state returns to
the STANDBY state or moves to the OFF state.
When the QUBE Fiber Laser is configured to ramp down via the Parameter Set, this
function will be CLEAR when the ramp down has completed and output has stopped.
This output function remains SET for the duration of a configured ramp down time
following the issue of a Laser STANDBY command either by a configured Machine
Interface Laser ON input function (CLEARED under Remote Control) or a Laser
STANDBY serial command message.
b) Process Cycles mode:
This output function will be SET following a Process Cycle Start command from either
a configured Machine Interface Process Cycle Start input function (SET under Remote
Control), or a Process Cycle Start serial command message.
Output function will be CLEAR when a Process Cycle completes, or the Process Cycle
is stopped from either a configured Machine Interface Process Cycle Start input
function (CLEARED under Remote Control), or a Process Cycle Stop serial command
message.
When a Process Cycle is terminated; if the current step being executed is referencing
a Parameter Set with a ramp down time defined, this output function remains SET for
the duration of a configured ramp down time following the issue of a Process Cycle
Stop command either by a configured Machine Interface Process Cycle Start input
function (CLEARED under Remote Control) or a Process Cycle Stop serial command
message.
This function can be assigned to any of the seven outputs.
Associated functions
o Laser ON / Process Cycle Start - Input Function
o Laser STANDBY - Output Function
Sequence diagrams
o See Figure 42 to Figure 66 for example functionality.
11.3.3 Remote Control (Output Function ID 3):
Default connection
o PL5 pin number 20
o Output number 2
Basic Function Description
o SET when in Remote Control.
o CLEAR when t in Local Control.