EasyManua.ls Logo

SPI Lasers redPOWER QUBE - 11.2.5 Alarm Reset (Input Function ID 6)

SPI Lasers redPOWER QUBE
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2016 SPI Lasers UK Ltd.
Commercial in Confidence
SM-S00500 Revision A 21 October 2016
redPOWER QUBE Cased Fiber Laser User Manual
103
Figure 61 Advancing Process Cycle Steps in Remote Control(Before Process Cycle
Wait Is Set)
Note: The second Process Cycle Step input advances the process cycle as the leading edge
occurs while the Process Cycle is waiting to advance.
11.2.5 Alarm Reset (Input Function ID 6):
Default connection
o PL5 pin number 18
o Input number 4
Basic Function Description
o Resets QUBE Fiber Laser (normally after an alarm condition has occurred, and
the cause has been cleared).
o Input is leading edge sensitive.
o Only operational in Remote Control.
Detailed Function Description
o This input function allows the QUBE Fiber Laser to be reset via the Machine
Interface. It Triggers when the input transitions from CLEAR to SET only. The
function can be used following an alarm condition, once the fault has been
identified and cleared, to clear the latched alarm state.

Table of Contents