redPOWER QUBE Cased Fiber Laser User Manual
o Input is edge sensitive in Remote Control.
o Input is level sensitive when entering Remote Control.
Detailed Function Description
o SETting the input sequences the state to the STANDBY state.
o CLEARing the input switches the state to the OFF state.
o When switching into Remote Control, the state of the Laser Start input is acted
upon depending on the state of the QUBE Fiber Laser as follows:
When the state is OFF, and Laser Start input is SET, the state will
remain OFF when entering Remote Control. The Laser Start input must
detect a positive edge to change the state. Alternatively a software
command can be issued to sequence the state to the STANDBY state
while the input remains SET.
When the state is the STANDBY or the ON state, and Laser Start input
is CLEAR, the state will switch to the OFF state when entering Remote
Control. In this case, the Laser Start input is level sensitive. While in
Remote Control, the only way to sequence the state into the STANDBY
state is to SET Laser Start.
When the state is the STANDBY or the ON state, and the Laser Start
input is SET, the state will not switch to the OFF state when entering
Remote Control. In this case, the state of the Laser Start input is level
sensitive and the state is also dependant on the Laser ON / Process
Cycle Start input.
o Therefore, care must be taken to ensure the Laser Start input (if configured) is
in the correct state when entering Remote Control.
This function has no effect if it is not configured on the Machine Interface.
This function can be assigned to any of the seven inputs.
Associated default functions
o Laser STANDBY - Output Function
o Remote Status - Output Function