redPOWER QUBE Cased Fiber Laser User Manual
96
Figure 50 Starting a Process Cycle in Remote Control
Note: The state can be moved to the ON state using a serial protocol message, as long as
Laser Start is SET.
Process Cycle Start can be asserted at any time to start a Process Cycle as long as the state
is the STANDBY state.
There is a small switching delay before Process Cycle Start is acted on (<1ms) and Process
Cycle Active is SET.
Figure 51 Stopping a Process Cycle in Remote Control
(No ramp down time configured in active step Parameter Step)