STIHL TS 460 59
9.7 Handle Ba
r
Top: Removing the
mounting screw
Bottom:
Annular buffer
Top:
1 =Annular groove
2 = Annular rib
Bottom:
1 = Pressure plate
2 = Mountin
g
screw
Top:
1 = Short circuit wire
2 = Ground wire
3 = Throttle cable
Bottom:
AV-molding
mounting screws
- Unscrew mounting screw
of annular buffer.
- Remove handle tube bracket.
Note: Follow the same procedure
in removing the handle tube
bracket on the other side.
- Press annular buffer out of
handle tube bracket.
The parts are assembled in
reverse order.
Note: Press in annular buffers
until annular groove engages
annular rib on handle tube bracket.
Insert pressure plates in annular
buffer. Screw in screw and tighten
to 8.0 Nm.
- Remove contact springs, see 9.3.
- Pull short circuit and ground
wires and throttle cable out of
handle grip.
- Unscrew mounting screws for
AV-molding, remove AV-molding.