STOBER 8 | Commissioning
02/2020 | ID 442516.07
41
8.3.4 Configuring synchronization using distributed clocks
ü
You have fully configured the associated axis model in DriveControlSuite. As the more precise of the two sync
methods, synchronization using distributed clocks (DC-Sync) is pre-configured in the EtherCAT master and slaves.
1. Navigate to the EtherCAT master in the solution explorer.
2. In the main window, switch to the EtherCAT tab and click Advanced Settings.
ð The Advanced Settings dialog box opens.
3. In the tree view, select Distributed Clocks.
4. Automatic DC Mode Selection:
This option must be activated.
5. Close the dialog box.
6. In the tree view, navigate to the first EtherCAT slave.
7. In the main window, switch to the DC tab and click Advanced Settings.
ð The Advanced Settings dialog box opens.
8. Enable:
This option must be activated.
9. DC enabled (multiplier = 1):
This list entry must be selected.
10. Sync Unit Cycle (µs):
Check the default value for the cycle time of the controller and change it if necessary.
11. Enable SYNC 0:
This option must be activated.
12. Close the dialog box.
13. Repeat steps 7 – 12 for each additional slave in your EtherCAT network.
ð The EtherCAT master and slaves will now be synchronized with the first EtherCAT slave that has the distributed clocks
option enabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stober EtherCAT SD6 Series and is the answer not in the manual?

Stober EtherCAT SD6 Series Specifications

General IconGeneral
BrandStober
ModelEtherCAT SD6 Series
CategoryController
LanguageEnglish

Related product manuals