EasyManua.ls Logo

Stober EtherCAT SD6 Series - Parameters; A255 | Ethercat Device State | V2; A256 | Ethercat Address | V1

Stober EtherCAT SD6 Series
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 | Monitoring and diagnostics STOBER
50
02/2020 | ID 442516.07
9.4 Parameters
The following diagnostic parameters are available for EtherCAT communication in combination with SD6 drive controller.
9.4.1 A255 | EtherCAT Device State | V2
State of the drive controller in the EtherCAT network (EtherCAT State Machine, ESM).
§ 0: invalid
§ 1: Init State
No communication between EtherCAT master and slave; the configuration starts, saved values are loaded
§ 2: Pre-Operational state
No PDO communication; the EtherCAT master and slave exchange application-specific parameters via SDOs
§ 4: Requested Bootstrap State
EtherCAT slave sends current actual values to the EtherCAT master, ignores its set values and refers to internal default
values
§ 8: Operational State
Normal operation: The EtherCAT master and slave exchange set and actual values
§ 17: Error - Init State – 21: Error - Operational State (Details: A257)
9.4.2 A256 | EtherCAT Address | V1
Address of the drive controller in the EtherCAT network (data source: EtherCAT master).

Table of Contents

Related product manuals