State transitions
§ IP: Start Mailbox Communication
Start of SDO communication over the mailbox channel.
§ PI: Stop Mailbox Communication
Stop of SDO communication over the mailbox channel.
§ PS: Start Input UpdateStart Input Update
Start of PDO communication over the process data channel.
§ SP: Stop Input Update
Stop of PDO communication over the process data channel; the slaves do not send any actual values.
§ SO: Start Output Update
The slaves evaluate the current set value specifications of the master.
§ OS: Stop Output Update
The slaves ignore the set values of the master and refer to internal default values.
§ OP: Stop Output Update, Stop Input Update
Stop of PDO communication over the process data channel; neither the master nor the slaves send actual or set values.
§ SI: Stop Input Update, Stop Mailbox Communication
Stop of PDO and SDO communication over the corresponding channels; neither the master nor the slaves send actual
or set values.
§ OI: Stop Output Update, Stop Input Update, Stop Mailbox Communication
Stop of PDO and SDO communication over the corresponding channels; neither the master nor the slaves send actual
or set values.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stober EtherCAT SD6 Series and is the answer not in the manual?

Stober EtherCAT SD6 Series Specifications

General IconGeneral
BrandStober
ModelEtherCAT SD6 Series
CategoryController
LanguageEnglish

Related product manuals