Part 1: User Level  WSPC USER INTERFACE 
17 
Compressor loaded hours – Total number of hours the compressor has run 
loaded. 
Compressor full load hours – Total number of hours the compressor has run at 
full load. 
Number of starts – Total number of times the compressor has been started 
automatically or manually.  
Number of load cycles – Total number of load cycles the compressor has 
completed.  
 
3.2.2 Digital Inputs and Relay Outputs  
The digital inputs and relay outputs indicate that a signal from an input/output 
device has been received. 
Digital Inputs – Each indicates that the input has been activated by a machine 
action.  When active, the box next to the input will be bright green in color. 
E-stop – Indicates that an emergency stop switch has been pressed.  The E-stop 
is normally closed and the box next to the E-stop input is bright green.  When the 
button is pressed, the E-stop input indicator will appear dark. 
Relay Outputs – Each indicates that the output relay has been activated by the 
controller.  When active, the box next to the output will be bright red in color. 
Inputs and outputs are assigned at the factory to indicate specific actions, and 
will vary with the compressor model.  Typical factory assignments of inputs and 
outputs are as follows: 
 
Digital Inputs:  Definition  Relay Outputs: Definition 
Input 1: 
Main Motor Overload-Fault 
Output 1:
Run 
Input 2: 
Aux. Motor Overload-Fault 
Output 2:
Wye 
Input 3: 
Starter Aux. Contact-Fault 
Output 3:
Delta 
Input 4: 
NOT USED 
Output 4:
Load 
Input 5: 
High Air Filter dP-Warning 
Output 5:
Full Load 
Input 6: 
High Fluid Filter-Warning 
Output 6:
Drain 
Input 7: 
Remote Unload (Option) 
Output 7:
Fault Signal 
Input 8: 
Fault (Option)   
Input 9: 
Warning (Option)   
E-Stop: 
Emergency Stop Activated