Part 1: User Level WSPC USER INTERFACE
19
Cooling – Method of cooling (air cooled or water cooled)
Motor –The motor control (Y-delta, full voltage, variable -speed)
Volts – Nominal Starter line voltage
Dryer – Dryer type
3.4 SERVICE DISPLAY
The Service display provides information related to compressor events which
require service actions. A history of the 16 most recent fault messages are
displayed on the service page along with information detailing the time and date
of the fault occurrence. See Figure 3.4. The fault history can aid the user in
identifying related events and recurring problems that may cause machine
malfunctions or limit operation. Refer to the WS Controller User Instruction
Manual for actions to be taken when a fault or warning condition occurs.
The first row of the fault listings displays the most recent fault.
Column one provides a description of the fault cause.
Column two displays the number of hours the compressor has run when the fault
occurred.
Column three shows the month and day on which the fault occurred.
The remaining columns display the time of day that the fault occurred in
hour:minutes:seconds.
Figure 3.4 Service Display