WSPC USER INTERFACE Part 2: Administrator Level
58
Figure 6.1 Password Entry Box
4. The WSPC program will open with access to Administrator Level
Functions.
If the program opens without displaying a password entry field then a User level
profile was selected. Click on the down arrow next to the User Name field and
select an Administrator profile for access to administrator level functions.
6.3 COMMISSIONING A CONTROLLER
Commissioning is the process of initializing the WS Controller for operation with a
specific compressor model and type. During the commissioning process, all
previous stored data (parameter values, logs, history information, etc.) is erased
from the controller memory. The new default parameter values are then loaded
to the controller that configure it for a particular compressor model and
application.
To commission a controller for a compressor model:
1. On the Menu Bar select the “File” menu and click “Commission” in the
drop-down option list. See Figure 6.2. The “Commission” window will be
presented.
Figure 6.2 Commission Option
NOTE
Controller commissioning is normally a one-time event when a new
controller is installed.
The compressor must be stopped before beginning the
commissioning process. When the compressor is running, the
“Commission” option is inoperable.
Commission