WSPC USER INTERFACE Part 1: User Level
22
Figure 3.8a Saved Sensor Log File Example
3.4.2 Log Data Button
WSPC may be used to log data about compressor operation for extended
periods. These files are stored in the PC. A line of data is stored at least once
per minute. Additional data lines are stored if any significant change occurs. A
“Logging” indicator is bright green whenever logging is turned on. This is
intended as an aid for troubleshooting. This report may be viewed as a text file,
or imported into a spreadsheet for formatted analysis and graphing.
Figure 3.8b Data Log File Example
The data on each line includes:
1. The time of the record
2. The WS Controller operating mode
3. The compressor operating state
4. Digital input and Output condition (shown as a hex number)
5. Data from all 11 analog inputs, including temperatures and pressures
6. Data from the variable frequency drive.