SummaCut Series Cutters User’ s Manual
Operation 2-11
2.2.22. FLEX CUT LENGTH
This parameter determines the length that will be cut with reduced pressure or
without pressure. By clicking on the ‘Cut Test Pattern’ button, the FLEX-CUT test
pattern will be cut.
2.2.23. FLEX PRESSURE
This parameter determines the pressure of the FLEX-CUT LENGTH. By clicking on
the ‘Cut Test Pattern’ button, the FLEX-CUT test pattern will be cut.
2.2.24. RECUT OFFSET
The recut offset submenu is used to set or modify the distances between the
drawings when making multiple recuts.
The default recut offset value is 0 mm.
The distance can be set between o and 255 mm.
On the LCD, the active recut offset value is marked with an *.
2.2.25.RECUT
The Summa Cutter Control program also offers the possibility to recut the last
file sent to the cutter (provided that it fitted into the buffer).
To make a recut, proceed as follows:
1. Cut the file once with your usual software.
2. Start up the Summa Cutter Control program. Make sure that the port is
correctly configured.
3. Press the Recut button.
4. Select the desired number of copies and the recut offset