User Manual 10 Appendix
Parameters SG110CX SG110CX-20
Allowable relative hu
midity range
0 ~ 100%
Cooling method Smart forced air cooling
Max. operating alti
tude
4000 m (> 3000 m derating)
Display LED, Bluetooth + APP
Communication RS485/ Optional: WLAN, Ethernet
DC connection type MC4 (Max. 6 mm
2
)
AC connection type OT or DT terminal (Max.240 mm
2
)
Grid Support
Q at night function, LVRT, HVRT, active & reac
tive power control and power ramp rate control
EMC
(6)
EN 55011:2016/A1:2017/A11:2020/A2:2021,Group 1,class A
Note(1): The inverter enters the standby state when the input voltage ranges between 1,000V
and 1,100V. If the maximum DC voltage in the system can exceed 1000V, the MC4 connectors
included in the scope of delivery must not be used. In this case MC4 Evo2 connectors must
be used.
Note(2):The voltage difference between MPPTs should be less than 80 V. The voltage of the
configured string should be higher than the lower limit of the rated MPPT voltage.
Note(6):This standard is applicable only to the European region.
Parameters SG110CX
(3)
SG110CX-NI
(3)
Input (DC)
Recommended max.
PV input power
147 kW
Max. PV input voltage 1100 V
(4)
Min.PV input volt
age/Start-up input
voltage
200 V / 250 V
Nominal input voltage 585 V
MPP voltage range 200 V ~ 1000 V
MPP voltage range
for rated power
550 V ~ 850 V
(5)
No. of independent
MPP inputs
9
No. of PV strings per
MPPT
2
Max. PV input current 234 A (26 A / 26 A / 26 A / 26 A / 26 A / 26 A / 26 A / 26 A / 26 A )