EasyManua.ls Logo

SunTech ST4940 - Page 24

SunTech ST4940
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Doc. Title
ST4940 User Manual
Concerning:
Rev.
Date (dd-mm-yy)
Page of Pages
Features and how to configure ST4940
1.07
0
1-7-2019
24 of 52
Default: 70
VI_OFF_THRES
1/255G
Threshold value for Motion Virtual Ignition Off
Range : 3~50
Default : 5
VI_OFF_DELAY
String
Second
Delay time for Motion Virtual Ignition Off
Range : 3~300
Default : 10
VI_OFF_PERCENT
String
%
Percent for Motion virtual Ignition Off
Range : 30 ~ 100
Default : 100
DEEP SLEEP
‘0’ or ‘1’
0 : Disable
1 : Enable
SPEED_LIMIT
String
km/h
Over speed limit
If 0, the device does not check the over-speed.
If greater than 0 and if the vehicle runs faster than the
predefined value, the device reports an alert once.
<Example>
[command]
ST600SVC;0123456789;02;1;5;10;70;5;10;70;0;200
[response]
ST600SVC;Res;0123456789;309;1;5;10;70;5;10;70;0;200
<Notes>
1. Driving or Parking is decided by Motion Sensor. If VI_ON_THRES is equal to zero, it cannot recognize
‘driving’. Please do not forget that the ST4940 may show you a bigger distance than the real one while
the vehicle is parked, if you make an optional configuration to enable the device not to check motion.
2. To use the ‘DEEP SLEEP’ option, ‘PARKING_INTRV should be one hour or more than one hour.
3. If “DEEP SLEEP” option is enabled, ‘the report of distance’ will always be ‘0’.
4. The device can be used to do tracking for a fixed asset. In this case, the following table shows how long
the endurance time of the battery lasts.

Table of Contents