8686
Malfunction Description Remedies
306:Temp mea. The AT solar inverter is
equipped with a temperature
sensor that monitors the heat
sink temperature. This message
appears if the sensor reports a
value outside its value range or
in case of a sensor cable break.
The ambient temperature of
the solar inverter is outside the
permissible range (< -25°C).
Wait until the temperature
reaches the permissible
operating range.
A cable break has occurred in
the sensor which monitors the
heat sink temperature.
Please contact the technical
hotline. The phone number
is provided on the back of
the manual.
Malfunction Description Remedies
307:Overtmp.
(Warning)
Your solar inverter is designed
for an ambient temperature of
up to +40°C. When a specied
temperature threshold of the
heat sink is reached, the output
power is reduced linearly.
Should the heat sink tempera
-
ture nevertheless continue to
increase, feeding is stopped.
This warning appears when the
current heat sink temperature
is just below the switch-off
threshold.
The maximum permissible
ambient temperature has been
exceeded.
The installation location
is not suitable. Please nd
another installation location.
The necessary air circulation
was not taken into account
during installation.
Clean the solar inverter, if
dirt prevents cooling.
Observe the installation
distances specied in the
manual.
Objects were laid on the heat
sink and unimpaired convec
-
tion was prevented.
Remove the objects.