87
Malfunction Description Remedies
306:Temp mea. The AT solar inverter is
equipped with a temperature
sensor that monitors the heat
sink temperature. This message
appears if the sensor reports a
value outside its value range or
in case of a sensor cable break.
The ambient temperature of
the solar inverter is outside the
permissible range (< -25°C).
➡ Wait until the temperature
reaches the permissible
operating range.
A cable break has occurred in
the sensor which monitors the
heat sink temperature.
➡ Please contact the technical
hotline. The phone number
is provided on the back of
the manual.
Malfunction Description Remedies
307:Overtmp.
(Warning)
Your solar inverter is designed
for an ambient temperature of
up to +40°C. When a specified
temperature threshold of the
heat sink is reached, the output
power is reduced linearly.
Should the heat sink tempera
-
ture nevertheless continue to
increase, feeding is stopped.
This warning appears when the
current heat sink temperature
is just below the switch-off
threshold.
The maximum permissible
ambient temperature has been
exceeded.
➡ The installation location
is not suitable. Please find
another installation location.
The necessary air circulation
was not taken into account
during installation.
➡ Clean the solar inverter, if
dirt prevents cooling.
➡ Observe the installation
distances specified in the
manual.
Objects were laid on the heat
sink and unimpaired convec
-
tion was prevented.
➡ Remove the objects.
87