Toubleshooting
AdvancedDisk
This chapter includes the following topics:
■ AdvancedDisk troubleshooting
■ Resolving an incorrect storage type problem
AdvancedDisk troubleshooting
The following may help you troubleshoot AdvancedDisk:
Table 6-1
AdvancedDisk troubleshooting
SolutionProblem
If NetBackup cannot access the storage, one possible cause
is that the storage server was created with the incorrect
nbdevconfig storage type (-st) value. An AdvancedDisk
storage server -st value is 5 (formatted disk, directly
attached); values other than 5 are incorrect.
More procedural information is available about resolving
this problem.
See “Resolving an incorrect storage type problem”
on page 52.
Unable to access storage
AdvancedDisk does not support Common Internet File
System (CIFS). If you try to configure multiple storage
servers, NetBackup returns the following message:
DSM does not support to use multiple Windows Storage Servers for
server type: AdvancedDisk.
Multiple storage servers on
Windows
6
Chapter