Appendix C Events
166 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
KEYGEN Indicated that the
Authentication Key table
is being generated
EQPT NA NA
SERVER Indicates that a user has
changed the NTP Peer
Server parameters.
EQPT NA NA
SYS Event Codes
BRDGTIM Bridging Time, in PRR
mode the amount of time
the system stays in
Bridging Mode
EQPT 900 seconds 300 to 500000 seconds | DISABLE
CLRDELAY The time, in seconds,
before a faulted signal
indicates it is valid to be
used as a system
reference.
EQPT 5 seconds 0 to 1000 seconds
ELEVTIME The alarm elevation time
(1440 minutes) was
Enabled or Disabled.
EQPT DISABLE ENABLE | DISABLE
FACTORY When the SYS is
commanded to reset to
Factory defaults, it
generates an event
indicating the factory
settings are being
restored. This resets all
modules installed in the
system at the time the
command is issued.
EQPT NA NA
FLTDELAY The time, in seconds,
before a faulted signal
indicates it is not valid to
be used as a system
reference.
EQPT 5 seconds 1 to 15 seconds
Table C-1. Event Identifiers (Continued)
Event ID
or
CONDTYPE
Event Description
AID
TYPE
Default Value Value Description

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals