097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 61
Chapter 2 TL1 Command Syntax and Description
Edit Sync (ED-SYNC)
Example
To provision the interface type of the inputs as T1 inputs:
Input
ED-SYNC::INP1:TP1000::FRMTYPE=D4;
Normal Response
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU
05-02-10 13:35:56
A 2556 REPT EVT
"INP1,T1:FRMTYPE,TC,05-02-10,13-35-56,,,,:\"INPUT FRAMING TYPE HAS
CHANGED,D4\""
;
HOLDFLT CUTTHRU Cut-thru mode is engaged when the Local Oscillator
enters Holdover mode.
RETIME
RETIME Cut-thru mode is not engaged when the Local
Oscillator enters Holdover mode.
<aid> = E422g
FRMTYPE 1.544M The framing type generated by the specified EIA-422
output group is provisioned as 1.544 MHz.
1.544M
2M The framing type generated by the specified EIA-422
output group is provisioned as 2 MHz.
FREEFLT ON Outputs are generated when the Local Oscillator
enters Free-run mode.
SQUELCH
SQUELCH Outputs are squelched (turned off) when the Local
Oscillator enters Free-run mode.
HOLDFLT ON Outputs are generated when the Local Oscillator
enters Holdover mode.
ON
SQUELCH Outputs are squelched (turned off) when the Local
Oscillator enters Holdover mode.
Note:
1
Used only in Japanese version.
Table 2-6. ED-SYNC – Keywords and Values (Continued)
<keyword> <value> Description Default

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals