Chapter 2 TL1 Command Syntax and Description
Retrieve Craft Data (RTRV-CRAFT)
94 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
clrdelay
The time that elapses after a signal fault clears and before the associated alarm condition
clears. This delay helps prevent an alarm from clearing before the signal is stable.
0 | 1 | ... | 1000
fltdelay The time that elapses after an LOS, AIS, or OOF fault occurs and before the
associated alarm condition is set. This delay helps prevent spurious alarms.
0 | 1 | ... | 15
inacttime The amount of user command inactivity time, which determines the amount of
inactivity time before the user is automatically logged off of the system.
0 (Disabled) | 100 | 101 | ... | 10000
logecho Indicates if login and logout events are echoed to the local terminal:
ENABLE | DISABLE
<aid> = IMC
ioc1comm
ioc2comm
Indicates if an IOC1(2) communication alarm currently is active.
IOC1(2)COMM-OK – no IOC1(2)COMM alarm is currently active
IOC1(2)COMM-ALM – an IOC1(2)COMM alarm is currently active
<aid> = COML | COMR
baud The serial port’s baud rate setting.
2400 | 9600 | 19200 | 38400 | 57600 | 115200
flow The type of serial port flow control set).
NONE | SW | HW | SWHW
echo Indicates if input is echoed to the local terminal on the port.
ENABLE | DISABLE
<aid> = COMI
ipaddr The IP address of the Network Element.
ipgate The IP address of the default gateway.
ipsubnet The subnet mask.
echo Indicates if input is echoed to the local terminal on the port:
ENABLE | DISABLE
<aid> = IOC1 | IOC2
Note: The following status conditions are reported by the IOC modules, but are stored in the IMC
module. When the RTRV-COND command is received by the unit, the IMC module reports the last
status conditions it received from the IOC modules. If IOC1(2)EQPT = UNEQUIPPED or
IOC1(2)COMM = ALM, then IOC data is not displayed.
iocstatus The current status of the specified IOC module.
OK | ALM
ioccomm Indicates if a communication alarm from the IOC1(2) to the IOC2(1) module is active.
IOC1(2)TO2(1)COMM-OK – no IOC1(2)TO2(1)COMM alarm is currently active
IOC1(2)TO2(1)COMM-ALM – an IOC1(2)TO2(1)COMM alarm is currently active
Table 2-16. RTRV-CRAFT Output Fields (Continued)
Field Description