getting started
17
Synrad Firestar f-Series operator’s manual
Inventory
Table 1-1 f100/f201 ship kit contents
Shipping Box Contents Qty Shipping Box Contents Qty
DC Power Cable ............................................1 Spare 20 Ampere Fuses (not shown) ..... 1/2
Quick Start Plug ............................................1 Chiller Fittings ............................................... 2
BNC Control Cable (f201 only) ..................1 Spherical Washer Sets (f201 only) ........... 3
Cooling Tubing ............................................... 1 Cooling Kit ...................................................... 1
Mounting Bolts ..............................................3/6 Final Test Report (not shown) ..................1
SYNRAD CO
2
Lasers Manual CD................1
f100/f201 contents description
Each item listed in Table 1-1 is described below:
DC Power Cable – carries DC power from the DC power supply to your Firestar laser.
Quick Start Plug – connects to Firestar’s User I/O connector. Jumpers are built into the plug to enable
Firestar’s shutter and remote interlock circuits for initial start-up and testing.
BNC Control Cable (f201 only) – Coaxial cable carries the PWM Command signal from the UC-2000
Controller to the laser’s Quick Start Plug.
Cooling Tubing – carries cooling water from the chiller to the laser and back. This black polyethylene tub-
ing is 1/2-inch O.D. by 30 feet and must be cut to length.
Mounting Bolts – fasten Firestar to your mounting surface. Three 1/4–20 × 3/4" UNC capscrews are pro-
vided for mounting Firestar f100 lasers. Firestar f201 lasers include three metric (M8 × 1.25 × 30 mm) and
three standard (5/16–18 × 1.25" UNC) capscrews.
SYNRAD CO
2
Lasers Manual CD – contains an f-Series manual that provides setup, operation, and main-
tenance information for your Firestar f-Series single-tube (f100/f201) or dual-tube (f200/f400) laser.
Spare 20 Ampere Fuses (not shown) – fast-blow fuses protects Firestar’s internal circuitry.
Chiller Fittings – adapt 1/2-inch O.D. tubing to 3/8" NPT threads for connection to a chiller. The chiller’s
inlet and outlet ports must be equipped with, or be adapted to, 3/8" NPT female threads.
Spherical Washer Sets (not shown) – used in conjunction with Firestar f201 mounting bolts to align the
laser to your mounting surface. Shipped with f201 lasers only.
Cooling Kit – adapts the laser’s straight 1/2-inch coolant ttings to 90° adaptor ttings for either 1/2-inch
standard or 12-mm metric cooling tubing.
Final Test Report (not shown) – contains data collected during the laser’s nal pre-shipment test.