technical reference
331
Synrad Firestar f-Series operator’s manual
f200 general specications
Parameter Firestar f200
Cooling Specications
Maximum Heat Load ............................................4000 Watts (13.7 kBtu/hr)
Flow Rate (minimum) ..........................................4.0 GPM at < 60 PSI (15.1 lpm at < 414 kPa)
Pressure Drop ..........................................................20 PSI at 4 GPM (138 kPa at 15.1 lpm)
Coolant Temperature
8
..........................................18 °C to 22 °C
Environmental Specications
Operating Temperature
9
.....................................15 °C to 40 °C
Humidity ...................................................................0–95%, non-condensing
Physical Specications
Length .......................................................................31.2 in (79.3 cm)
Width .........................................................................13.9 in (35.3 cm)
Height ........................................................................7.48 in (19.0 cm)
Weight .......................................................................80 lbs (36.3 kg)
* Specications subject to change without notice.
8 Firestar f200 lasers can be operated at coolant temperatures up to 24 °C (75 °F) in order to reduce problems associated with
condensation; however, this may result in decreased laser performance and/or reduced laser lifetime.
9 Published specications guaranteed at a cooling temperature of 22 °C.