3.9 Detector Control
To enable or disable a detector.
Press DET to enter the detector menu. The last accessed detector is displayed.
Whilst the detectors are shown, press DET repeatedly to scroll through the list of
available detectors. Alternatively, whilst the detectors are shown, use the arrow keys to
scroll through the list of detectors.
Use the 0 and 1 keys or Denom key to switch the selected detector on or off.
Continue to scroll through the list of detectors until all modifications are complete. Press
START/STOP to return to the counting display or wait for the display to time out.
Detectors in the list include:
Only detectors fitted to the machine will be displayed in the list.
Note: If you have selected SPEEd 5 and have activated one of the detectors shown
below. The machine will automatically reduce the speed to SPEEd 4. This is done to
enhance detector performance.
PPd (PPd), IR / FoiL (IR / FoiL), LonG Edge (LonG), SMDS (SnDS), MAgI (MAgI)
1. Display 7. Speed
2. Total 8. Det
3. Mode 9. Clear
4. Batch 10. Right Arrow
5. Start / Stop 11.Denomination
6. Auto 12. Left Arrow
13. Numeric Keypad
Short Short Edge Detection (SD)
LonG Long Edge Detection (LonG)
Enh Magnetics (Enh)
PrES Magnetic Presence (PrES)
Ub Ultra Violet (UV)
thd MTD Metal Thread (thd)
IR / FoiL Infra Red / Foil
SndS Superior Magnetic Detection System (SMDS)
PPd Paper Properties Detector. (PPd)
MAgI Full Width Magnetic Image Detector. (MAgI)