Chapter 5: Preset-Handling 22
5.3 Preset Information
The following request-message allows you to request information about a preset or the edit-buffer:
Sysex-start $f0
TC ID $33
Device# xx
Card# Unused, unless edit-buffer is requested
Packet-type $03 - Request Preset Info
<Preset#> Preset#
Sysex-end $f7
The M5000 will reply with the following:
Sysex-start $f0
TC ID $33
Device# xx
Card# Unused, unless edit-buffer is replied
Packet-type $05 - Preset Info
<Name> Preset-name
<Preset#> Preset# (original Preset# if edit-buffer)
<Byte> Algorithm-ID
<Byte> Edited, 0=FALSE, 1=TRUE
Sysex-end $f7
5.4 Recall Preset
This dump allows you to recall presets along the same path as the rest of your Sysex-
communications:
Sysex-start $f0
TC ID $33
Device# xx
Card# xx
Packet-type $02 - Recall Preset
<Preset#> Preset#
Sysex-end $f7
Please note, that if the M5000 front-panel is showing the program-recall page, the Preset# will start
flashing, because the preset you are in the process of recalling via the M5000 front-panel no longer
is the current preset (because of this Sysex-dump).