EasyManua.ls Logo

TDK-Lambda GH10-100 - Global Subsystem; Measure Subsystem

TDK-Lambda GH10-100
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
105
4.14.4 Global Subsystem
Global Commands General
Power Supplies acting upon Global Commands don’t have to be addressed.
All Power Supplies attached to the Interface must be capable of accepting Global Commands.
Global commands have no reply, execution only.
GLOBal:*RCL <NR1>
Function
Refers to *RCL <NR1> command description.
Parameters
1,2,3,4
GLOBal:*RST
Function:
Refers to *RST command description.
GLOBal:*SAVe <NR1>
Function
Refers to *SAV <NR1> command description.
Parameters
1,2,3,4
GLOBal:CURRent[:AMPLitude] <NRf+>
Function Refers to [SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
command description.
Units
A
GLOBal:OUTPut[:STATe] <Bool>
Function
Refers to OUTPut[:STATe] <Bool> command description.
Parameter
0|1, OFF|ON
GLOBal:VOLTage[:AMPLitude] <NRf+>
Function Refers to [SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
command description.
Units
V
4.14.5 Measure Subsystem
MEASure:CURRent[:DC]?
Query
Returns a measured output current.
Return
<NR2> - Current in Amperes, 5 digits format.
MEASure:VOLTage[:DC]?
Query
Returns a measured output voltage.
Return
<NR2> - Voltage in Volts, 5 digits format.
MEASure:POWer[:DC]?
Query
Returns a measured output power.
Return
<NR2> - Power in Watts, 5 digits format.

Table of Contents