85
4.10.4 Identification Commands
IDN?
Query Returns the power supply model identification as an ASCII string (one comma,
REV?
Returns the software version as an ASCII string
SN?
Returns the supply’s serial number. Up to 12 characters in any format
DATE?
Returns the date of last calibration. Format: yyyy/mm/dd
4.10.5 Initialization Commands
CLS
Clear Status. Sets FEVE and SEVE registers to zeroes
ADR <NR1>
Send ‘ADR’ and address (0 to 31) to open a communication channel.
<DSC> OK
RMT <DSC>
Function Set the power supply control source (front panel or communication) to local,
remote or LLO mode.
Local – Enable front panel control.
Remote – Disable front panel settings change (settings preview only).
LLO – same as Remote + Disable front panel unlock function by front panel.
Change mode by communication or AC recycle.