107
OUTPut:PON[:STATe] <DSC>
Function Determines the power supply output state after the AC recovery or non-
latching (OTP, ILC, ENA, DAISY_IN) faults.
SAFE Power supply output recovers to off state.
AUTO Power supply output recovers to prior failure state.
Parameter
0|1, OFF|ON, SAFE|AUTO
Query
OUTPut:PON[:STATe]?
Return
<Bool> 0|1
OUTPut:PROTection:CLEar
Function Clears latching faults (OVP, UVP and Foldback).
An actual fault condition must be removed before the latch is cleared.
The power supply output recovery according to OUTPut:PON state.
OUTPut:PROTection:FOLDback[:MODE] <DSC>
Function Foldback mode is used to disable the power supply output if a transition
between operation modes occurs.
Power supply turns output off after a specified delay if there is a transition
into CV mode or into CC mode. This feature is particularly useful for
protecting current or voltage sensitive loads.
Parameter
0|1|2, OFF|CC|CV
Query
OUTPut:PROTection:FOLDback[:MODE]?
Return
OFF|CC|CV
OUTPut:PROTection:FOLDback:DELay <NRf+>
Function
Sets the delay time from Foldback fault event to output disable.
Parameter 0.1 ~ 25.5 |MIN|MAX. Step: 0.1
Note: Round input parameter to the closest 100mSec step.
Unit
S
Query OUTPut:PROTection:FOLDback:DELay?;
OUTPut:PROTection:FOLDback:DELay? MAX
OUTPut:RELay1[:STATe] <Bool>
Function Sets PROG_OUT_1 pin (J1-21) in a rear panel connector. 0MOSFET is ON.
1 MOSFET is OFF.
Parameter
0|1, OFF|ON
Query
OUTPut:RELay1[:STATe]?
Return
<Bool> 0|1