159
-302 “General Error” Unrecoverable system error, recycle AC. If problem persists, contact
-304 "Advanced Slave Fault" Advance Parallel Fault - Slave unit communication error during
-305
"Advance Parallel Last Slave
Missing”
Advanced Parallel Last Slave unit is missing or not connected
Advanced Parallel waiting for slave unit to turn ON
-307 "Advanced Parallel Slave
Unrecoverable system error, recycle AC. If problem persists, contact
-308 “Advanced Parallel
Advanced Parallel connected units with different voltage or current
-309 “Memory Data Read/Write
Memory fault, can’t load/store data
-310 “Booster Mode” Booster power supply reply if communication is made through
-350 “Queue Overflow” Too many SYST:ERR messages are stored in error queue. Newest
Attempt to program voltage above OVP setting
Attempt to program voltage below UVL setting
Attempt to set OVP below voltage setting
Attempt to set UVL above voltage setting
Attempt to turn power supply output on when a fault exists
Under-Voltage protection shutdown occurred
AC Fail shutdown occurred
Over-Temperature shutdown occurred
Fold-Back shutdown occurred
Over-Voltage protection shutdown occurred
325 “Daisy-Chain In (SO)
Daisy-Chain In (Shut-Off) shutdown occurred
Output-Off occurred by front panel
Interlock shutdown occurred
Cannot execute command in Slave mode
Front panel power switch turned to OFF state
334 “Sequencer is ON” An attempt to set Constant Power Mode, Analog Programming, Slew
Rate or Internal Resistance while Sequencer is running or initialized
335 “Internal Resistance is ON” An attempt to set Constant Power Mode, Analog Programming, Slew
Rate or Sequencer while Internal Resistance is ON
336 “Constant Power Mode is
An attempt to set Internal Resistance, Analog Programming, Slew
Rate or Sequencer while Constant Power Mode is ON