159
Error Number
Error Description
Error Event
-302 “General Error” Unrecoverable system error, recycle AC. If problem persists, contact
service
-304 "Advanced Slave Fault" Advance Parallel Fault - Slave unit communication error during
operation
-305
"Advance Parallel Last Slave
Missing”
Advanced Parallel Last Slave unit is missing or not connected
-306
"Waiting for Slave Unit"
Advanced Parallel waiting for slave unit to turn ON
-307 "Advanced Parallel Slave
Unit General Error"
Unrecoverable system error, recycle AC. If problem persists, contact
service
-308 “Advanced Parallel
Mismatching Units”
Advanced Parallel connected units with different voltage or current
rating
-309 “Memory Data Read/Write
Failure”
Memory fault, can’t load/store data
-310 “Booster Mode” Booster power supply reply if communication is made through
Booster USB port
-350 “Queue Overflow” Too many SYST:ERR messages are stored in error queue. Newest
messages are discarded
301
“PV Above OVP”
Attempt to program voltage above OVP setting
302
“PV Below UVL”
Attempt to program voltage below UVL setting
304
“OVP Below PV”
Attempt to set OVP below voltage setting
306
“UVL Above PV”
Attempt to set UVL above voltage setting
307
“On During Fault”
Attempt to turn power supply output on when a fault exists
320
“UVP Shutdown”
Under-Voltage protection shutdown occurred
321
“AC Fault Shutdown
AC Fail shutdown occurred
322
“OTP Shutdown”
Over-Temperature shutdown occurred
323
“Fold-Back Shutdown”
Fold-Back shutdown occurred
324
“OverVoltage Shutdown”
Over-Voltage protection shutdown occurred
325 “Daisy-Chain In (SO)
Shutdown”
Daisy-Chain In (Shut-Off) shutdown occurred
326
“Output-Off Shutdown
Output-Off occurred by front panel
327
“Interlock Shutdown”
Interlock shutdown occurred
328
“Enable Shutdown”
Enable shutdown occurred
329
“Slave mode”
Cannot execute command in Slave mode
330
"System is powered off
Front panel power switch turned to OFF state
334 “Sequencer is ON” An attempt to set Constant Power Mode, Analog Programming, Slew
Rate or Internal Resistance while Sequencer is running or initialized
335 “Internal Resistance is ON An attempt to set Constant Power Mode, Analog Programming, Slew
Rate or Sequencer while Internal Resistance is ON
336 “Constant Power Mode is
ON”
An attempt to set Internal Resistance, Analog Programming, Slew
Rate or Sequencer while Constant Power Mode is ON