5. Record
5.1. Description
The Unit has following Saving Space structure
Record saves Impedance , Voltage, Temperature and Measurement time ,
Record saves Measurement 1, Measurement 2, Measurement time
Meter mode saves max 1000 measurements in record , record
String mode saves max 250 Strings.
Listed String used in , .
Each String can save 60 time Battery series in record. .
Each string record measurement saves as number of Cells (max 512 )
Each string save max 512 record.
[Refer below table]
5.1.1. Check Used Memory
To check used Memory, press to display percentage(%) of remaining memory at the upper
middle display .
When Unit is Power On, Message about remaining memory is displayed.