MX32v2
ANALOG AND DIGITAL CONTROLLER
USER MANUAL
Revision D.0
6.1.5 Digital linesThe cabling of the digital lines connecting the controller to the
different modules deployed along the lines are the subject of the paragraphs
OLCT 10N
Modules, 4- or 8-relay modules, 16-logic input modules, 8-analog input modules and 4-
analog output modules
of this same chapter. It should be remembered that this cable comes in 2
twisted pairs of 4 x 0.22 m² minimum, type MPI-22A, nominal impedance of 100 Ohms.
6.1.6 Analog or Wheatstone lines
For an analog 4-20mA detector connected directly to the
MX32v2
line, please wire the detector
as shown below.
Figure 25: 4-20mA detector connected to an analog line
In the case of a mV flammable gas detector connected directly to the
MX32v2
line, please wire
the detector as shown below.
Figure 26: connection of a Wheatstone type gas detector to a Wheatstone type
MX32v2
0V GND