MX32v2
ANALOG AND DIGITAL CONTROLLER
USER MANUAL
Revision D.0
5.7 4-Analog Output Module
Function
This digital module delivers 1 to 4 discrete opto-
isolated analog outputs deactivated
detectors can be assigned to one output allowing the
management of the lowest, highest and averaged
value. When non configured, the analog output is set
to 0mA. The module also features two logic inputs.
Figure 20: 4 Analog Output Module
5.7.1 Introduction
Figure 21: 4 Analog Output Module
A.
Logic Inputs
B.
Power supply and RS485 network
C.
DIP switches for module configuration
Push-button. Pressing this button forces all
outputs to 20mA
E.
(E1 to E4) discrete opto-isolated 4-20mA
analog outputs
F.
(F1 to F4) current output settings. Press D and
set to 20mA
A – Logic input connectorsEach of these two terminals may be connected to a voltage-free
contact in accordance with Figure 31
4-20mA outputs
2 logic inputs