64 | Section 5
Gated Receive AGC
Receive filter
Receive dynamic EQ
Ducker
Sample rate converter
Line Echo Canceller (hybrid)
Acoustic Echo Canceller (wideband)
Power Supply AC Input
Auto-sensing supply, 90VAC to 240VAC, 50 Hz to 60 Hz, IEC receptacle, internal fuse
Power consumption: 100 Watts
Operating Temperatures
-10 degree C to +40 degree C, <90% humidity, no condensation
Dimensions and Weight
3.5 inches x 17 inches x 15 inches, 10 pounds
Studio Audio Connections
Via Livewire IP/Ethernet. Each selectable group and fixed line has a send and receive
input/output.
Each studio has a Program-on-Hold input.
Each Acoustic Echo Canceller has two inputs (signal and reference) and one output.
LW-equipped studios may take the audio directly from the network. Interface Nodes are avail-
able for pro analog and AES3. (uses standard Livewire Nodes)
Telco Connections
Audio: standard RTP. Codecs: g.711u-Law and A-Law, and g.722.
Control: standard SIP trunking
Resources
Internet Speed tests
www.speakeasy.net
www.speedtest.net/
Internet VOIP Jitter Test
myspeed.visualware.com/indexvoip.php (free)