5.3.6 System Time Configuration
TENDA# clock set 14:09:30 4 11 2012
Note: Manually set system date and time to Apr 11 2012 and 140930 respectively
TENDA(config)# sntp enable
Note: Enable SNTP server
TENDA(config)# no sntp
Note: Disable SNTP server
TENDA(config)# sntp preferred-server 192.168.111.79
Note: Set Primary SNTP Server IP address to 192.168.111.79
TENDA(config)# sntp alternate-server 192.168.111.78
Note: Set Secondary SNTP Server IP address to 192.168.111.78
TENDA(config)# sntp broadcastdelay 100
Note: Set Sync Interval to 100s
TENDA(config)# clock timezone GMT-0800
Note: Set Time Zone to (GMT-0800)Beijing
5.3.7 Reset and reboot
TENDA# erase startup-config
Note: Delete all current settings and restore device to factory default settings
TENDA# reload
Note: Reboot switch (To restore factory defaults, system first deletes current settings and then
restarts)
5.3.8 Firmware Update
TENDA# archive download-sw 192.168.111.79G3224_V100R004.bin
Note: Load firmware from a TFTP server for upgrade
TENDA#archive startup-config 192.168.111.79mib.conf