User Guide
145
1. Specify a view name, say, qq.
2. Specify a MIB subtree OID, say, 1.2.1.
3. Specify a view rule from the drop-down list.
Enable Trap
To config SNMP Trap settings, click Device Management -> SNMP -> Enable Trap as below:
By default, the SNMP Trap feature is enabled on each port. Available generic Traps include:
Coldstart-Trap: Send Coldstart Trap to designated host when device is undergoing a coldstart (power
disconnection or reboot).
Warmstart-Trap: Send Warmstart Trap to designated host when the SNMP is disabled on the switch.
Linkdown-Trap: Send Linkdown Trap to designated host when an up link becomes down.
Linkup-Trap: Send Linkup Trap to designated host when a down link becomes up.
Authentication-Trap: Send Authentication failure Trap to designated host when SNMP module encounters
an authentication failure.
This section is only for enabling the SNMP Trap feature. See the following for configuring the Trap Host to
which Traps are to be sent.
Trap Setup
To enter the interface for configuring the host to which Traps are to be sent, click Device Management ->
SNMP -> Trap Setup as seen below.