Troubleshooting
10_Troubleshooting_en.fm - V 0.1 - 14.4.11
173 / 187
10
17
Malfunction Hydrostatic travel drive without neutral position
Cause • Switch for travel direction damaged
• Solenoids of valve damaged
• Neutral position incorrectly adjusted
• Internal damage to travel pump
• Excessive engine idling
Remedy Only Terex-customer service personnel are permitted to undertake the following
type of work.
Replace or repair direction switch
Check / re-calibrate solenoids of valve (call Service Agent)
Replace travel pump
Re-adjust engine idling
Malfunction Hydraulic oil exceeds max. admissible temperature
Cause • Thermo switch damaged
• Oil level too low
• Oil cooler dirty or damaged
• Suction filter clogged
• High-pressure valves do not respond all the time or too early
• Flushing circulation not functioning
• Travel pump or travel motor damaged (wear)
• Loader pump worn
• Main pressure relief valve damaged
Remedy
Replace suction filter
Top up oil to mark on dipstick
Clean, check and, if necessary, replace oil cooler
Only Terex-customer service personnel are permitted to undertake the following
type of work.
Replace thermo switch
Check high-pressure valves, re-adjust or replace if necessary
Check pressure of flushing and charge pump, possible back pressure in
cooling circuit, check housing pressure
Replace travel pump or travel motor
Replace working pump
Replace main pressure relief valve

Table of Contents