TL260
Troubleshooting
178 / 187
10
10_Troubleshooting_en.fm - V 0.1 - 14.4.11
17
10.3.1 Immobilizer faults
Malfunction Immobilizer has no function
Remedy
Inspect voltage supply on plug contacts.
Check antenna plug-in connection.
Check antenna cable.
Use key with learned transponder.
Malfunction Key learning not possible
Remedy
Terminal 30 not connected to control unit.
No or incorrect master key used previously (red grip).
Time for master key in ignition too short or too long.
Key to be learned does not have transponder.
Defective antenna.
Learning time for key in ignition too short.
Malfunction Clearing of learned keys not possible
Remedy
No or incorrect master key used (red grip).
Time for master key in ignition lock too short.
Defective antenna.