20
6 Setting up the power supply EX-TRAFIRE
®
105HD
For the input voltage and the fuse protection, please refer to:
4.2 Technical data on page 12
If necessary, have a certified electrician or trained personnel connect
the input power cable extension in accordance with local regulations.
Ensure that the power supply is adequately protected by a safety switch.
Insert the input power plug of the input power cable into the
corresponding socket.
6.4.1 Connection to a generator (optional)
Set the generator to three-phase alternating current.
Plug the input power plug into the socket.
Set the motor rating as shown in the following table.
Risk of electric shock due to improperly installed or defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
Check all live cables and connections for proper installation or
damage.
Damaged, deformed or worn parts should only be replaced by a
certified electrician or trained personnel.
Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious
injury.
Ensure that the operating voltage specified on the identification plate
is suitable for the input voltage.
Table 10 Connection to a generator
Generator rating Generator output
current
Generator output voltage
≥ 30 kW, 3-phase 60 A at 208 V AC
30 A at 460 V AC
25 A at 575 V AC
208 V AC, 460 V AC or
575 V AC (depending on
the specific power supply)