105HD 9 Maintenance and cleaning
35
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift
operation. We recommend recording the inspections. The date of the
inspection, the detected defects and the name of the inspector should be
documented.
Table 12 Maintenance and cleaning intervals
Daily/every 6 hours
of cutting
Check the gas settings.
Check cables, connector hoses, and
connections for tight fit and damage, and
replace, if necessary.
Check the work lead clamp for contamination.
Check the cutting torch's consumables for wear.
Weekly Check the cap sensor.
Every 3 months
Check the cutting torch for signs of cracks in the
torch body, and exposed wires.
Check the gas hose, filter elements and
connections for leaks.
Open the EX-TRAFIRE
®
105HD body and have
the inside cleaned with a vacuum cleaner or dry,
clean compressed air by Thermacut
®
or trained
personnel.
Annually and after
each time the
housing is opened
Have a safety inspection performed by
Thermacut
®
or trained personnel.