iCNC PERFORMANCE
3-22 OPERATION Manual 0-5399
SD1, SD2 and SD3
These delays are typically not used when using plasma as the marking device, but are fully available and programmable.
SD4
Typically used for starting the Initial Height Sensing and igniting the marker.
Move Delay
Delay before motion will begin.
ED1
Typically delay to wait the arc to extinguish.
ED2
This delay is typically not used.
ED3
This is the time that the controller waits after the marking is completed (torch up), before commanding the machine to move to the next
position.
3.14.3 Point Marking
SD1
This delay is typically not used but is fully available and programmable.
SD2
Typically used for a marker down delay. This is the time that it takes for the marker to descend to marking height.
SD3
This is the marking time, or the time the marking takes place. If using plasma as the marker device this would be the depth of the mark.
SD4
This is a marker-up raise time, or the time it takes for the marker to climb up to travel height.
Move Delay
This delay is typically not used.
Rapid
This delay is typically not used.