EasyManua.ls Logo

TKS K2 - Page 56

TKS K2
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TKS Operator's manual
56
5 Ceiling rail unit
error direction
The machine is driving
in the opposite direction
to the
sensor counters
Ceiling rail unit motors
are rotating the wrong
way
The position counter
sensors are connected
incorrectly
Contact an electrician and
reverse the
direction of operation of the
motors
Change location of the cable
to position counter A and B
Ceiling rail unit,
the machine has
moved without
operation
The machine has moved
without the ceiling rail
unit motor being
enabled
The machine was
pushed by an animal
or moved manually
7 Obstruction
detected!
The machine’s obstruc-
tion
function has been
triggered.
An obstruction has
been encountered
The machine has
collided with an
obstruction three times
in the same place
The obstruction
function’s sensitivity is
too high
Remove the obstruction
Reduce the obstruction
sensitivity
8 Synchronisation
warning
The synchronisation
impactor was struck too
far from the point
specifi ed
(further than 30 cm from
the impact)
Incorrect calibration
The synchronisation
impactor has shifted
out of position or has
been moved without
being recalibrated
The pulse wheel slips
against the rail, is dirty
or does not rotate
smoothly
The synchronisation
Perform a new calibration
Check that the pulse wheel
rolls freely
Tighten the tension of the
spring
Clean the wheel
Replace worn wheel.
Replace the sensors or
cables
9 Drum error The drum does not
rotate when the control
starts dispensing feed
The drum has stopped
because of jammed
feed
Fuse – F4 has tripped
The V-belts slip or are
defective
Drum sensor or cable
are defective Drum
sensor has shifted out
of position rotation
sensor is not working
properly
Remove jammed feed
Reduce supply of feed to the
drum using
conveyor belt settings
If the fuse has tripped, the
machine must wait 20 min
before restarting. Press
Reset Alarms and the fuse is
automatically reset
Check the V-belts and
tension
Check the drum sensor and
the cable
Check that the sensor is
counting