Loading...
TKS Operator's manual
57
10 Side dispenser
error!
Side dispenser does not
rotate when the control
starts the dispensing
process
The side dispenser has
stopped because of
jammed feed
Fuse – F5 has tripped
The belt is broken
Side dispenser sensor
or cable are defective
Side dispenser sensor
has shifted out of
position
Remove jammed feed
If the fuse has tripped, the
machine must wait 20 min
before
restarting. Press Reset
Alarms and the fuse is
automatically reset
Check and adjust the tension
on the belt so that it bends in
both rotation directions
Check the side dispenser
sensor and cable Check that
the sensor is counting
11 Maintenance
required
It is time to perform
maintenance on the
machine
The 10-hour
maintenance interval
since the previous
maintenance engineer
reset the maintenance
counter in the Hour
meter menu has
elapsed.
Maintenance must be
performed.
Once maintenance is
complete, reset the
maintenance counter in the
menu Hour meter
12 FK1 fault Error in
the inverter for the
ceiling rail unit
Incorrect voltage
Overload in the ceiling
rail unit motors.
Check power supply and
conductor rail
Check ceiling rail unit motors
Check that the rail track is
free of obstructions
13 FK2 fault Error in
the inverter for the
conveyor belt
Incorrect voltage
Overload in conveyor
belt motor
Check power supply and
conductor rail
Check if the conveyor belt is
stuck.
It should rotate freely
14 FK1
Communication
fault
Communication error
between PLC and
the inverter for
the ceiling rail
unit – FK1
Communication with
the inverter has been
lost
Reset error message and try
again
If the error recurs – contact
service personnel

Table of Contents